1dl code on goodman furnace - I need your assistance with the Amana and Goodman furnace E5 error code.After the LED segment 2 shows you E and the segment one shows the 5, this is one of t...

 
Feb 10, 2023 · 67. Ambient Temperature Sensor Fault (Out of Range – Open or Shorted) ERR 67. 6 Flash. Coil Temperature Sensor Fault (Out of Range – Open or Shorted) Low Pressure Cut Out Fault (Open outside of defrost Cycle-Hard lock out, cycle power to reset) ERR 79. . Papa johnpercent27s deals menu

Possible Causes for 4 flashes on a Goodman furnace. • Check filters andductwork for blockage.Clean filters or removeobstruction. circulator blower speed, orfailed circulator blower. • Check circulator blowerspeed and performance.Correct speed or replaceblower if necessary. • Misaligned burners, blockedflue and/or air inlet pipe, orfailed ...View and Download Goodman AVPTC42D14 series installation & operating instructions manual online. AVPTC**14 series. AVPTC42D14 series air handlers pdf manual download. Also for: Avptc48d14 series, Avptc30c14 series, Avptc36c14 series, Avptc24b14 series, Avptc48c14 series, Avptc60d14...Jul 13, 2022 · Goodman furnaces are among the most recognized and respected forced-air heating systems. Its reputation was built on a foundation of quality core product development, manufacturing excellence, and engineering expertise. Keeping that reputation alive means continuous improvement through product innovation and the introduction of new features reflecting advances in technology. Many components ... code (if there is no fault or protection code it will be display “nn”) Normal display Display “--” Operating mode 3—Heating; 4—Forced cooling) Operating fan speed grade (0—Power off) The total capacity requirements of the interior unit The capacity requirements of the revised external unit T3 piping temperature T4 environmert ... code (if there is no fault or protection code it will be display “nn”) Normal display Display “--” Operating mode 3—Heating; 4—Forced cooling) Operating fan speed grade (0—Power off) The total capacity requirements of the interior unit The capacity requirements of the revised external unit T3 piping temperature T4 environmert ... Select the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button.The flashing LEDs on your furnace will correspond to a specific fault code that is shown here on their diagnostic chart.Goodman is one of the biggest names i...Dec 23, 2022 · Goodman manufacturing. it is displaying code 1dl and the green light is flashing two long, five short. anything I can - Answered by a verified HVAC Technician View the user manual below for more details. Want a copy for yourself? Download or print a free copy of the user manual below. GAS FURNACE (INSTALLOPERATING) (viewing) Download PDF. Owner’s Manual. Top Parts. Models. Showing 10 of 12 parts. Show.Sep 29, 2022 · If the furnace is running, turn the thermostat off and allow the furnace to cool and the blower to stop operating. Initiate a call for heat from the thermostat and monitor the ignition sequence. 1. The inducer motor should start with no difficulty. 2. The pressure switch should close within a couple seconds of the inducer starting. 3. Besides Goodman fault codes, there are the messages which can also appear, status and data related to these codes. This information can give you the idea about any necessary further actions – for example, 3 flashes mean that Goodman pressure switch stuck open, and 2 flashes mean the same part stuck closed.Jul 27, 2022 · I have problem with bryant furnace mod#379CAV036070AGJA just to call for heat the board display code #12 (HK42FZ011) so we wait some time and after that the board run a perfect cycle,run inducer,fire … Welcome to TWINTECH Heating & Cooling Keeping families comfortable for over 30 years. Check out our seasonal promotions. TWINTECH is a full-service HVAC care and maintenance provider located in Durham, Ontario.goodman furnace codes The flashing LEDs on your furnace will correspond to a specific fault code that is shown here on their diagnostic chart. Goodman is one of the biggest names in home heating and energy efficient home comfort. Turn off power to the furnace and check the inlet gas pressure. Minimum Pressure = 5" w.c. for Nat. Gas, and 11" w.c. for Propane. No or Low Pressure = Bad Meter or Regulator; Normal Pressure ⇒ Continue; Re-apply power to the furnace and activate a call for heat. Make sure the inlet gas pressure stays above minimum when the gas valve energizes.Jul 13, 2022 · Goodman furnaces are among the most recognized and respected forced-air heating systems. Its reputation was built on a foundation of quality core product development, manufacturing excellence, and engineering expertise. Keeping that reputation alive means continuous improvement through product innovation and the introduction of new features reflecting advances in technology. Many components ... Jul 1, 2022 · Brand new and it is a goodman ace furnace dont have the model number with me. Tried the reset - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website. Troubleshooting GMEC96 Fault Status Codes •Fault Code Example 1: Status light displays “4 Red flashes.” •Refer to the “troubleshooting” chart on page 44 of the GMEC96 service manual. •Also, find your “fault symptoms and description” in the troubleshooting chart on pages 42-43.Once again Twin Tech came through and fixed my furnace. A young man by the name of Mitch came by tonight and he was so nice explained everything he was quick he was clean he turned off the lights even when he left the furnace room it s just above and beyond Twin Tech always delivers and I just found out about them last year and I will use no one else but thanks again Mitch you are fantasticMar 26, 2022 · I am always available if you want to use your “Request Call Option “ And if you don’t get another message right after this greeting it’s because I’m more then likely I’m in the process of writing another message to you. that number is ***** the air conditioning coil that is on top of the furnace. How to Replace Your Air Filter. Open the access door on your Goodman furnace by pulling it towards you, revealing the filter inside. Carefully remove the filter by hand. Vacuum any dust or debris that may have accumulated on the filter housing of the furnace. Slide in the replacement filter.Troubleshooting b1 fault code on a Goodman communicating air handler HVAC Technician: airheatman , HVAC Technician replied 7 years ago Take a look at this manual on troubleshooting these motors and let me know if you want to get the tester and determine if issue is in motor or board1dl code has appeared on our Goodman ac, Yes to both. Since last night, reset everything, ... I hav e GMV95 Goodman Furnace and air about 6 months old. Air has worked ...Jan 25, 2020 · 1. the thermostat demand signal is intermittent. 2. Time delay relay or control board faulty. 3. If high pressure switch is present, go to Flash Code 2 information. 4. If a low pressure switch is present, go to Flash Code 1 information. Status LED: Yellow “ALERT” Flash Code 4. Status LED Description: off rotor. https://www.alwaysopen.caGoodman Furnace Fault CodesInstructions: 1. Select the brand from the drop down menu 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button. © 2011 Goodman Manufacturing Company, LP. All rights reserved.GOODMAN GAS FURNACE IO MANUAL GMS8 GDS8 GHS8 [PDF] (2005) Gas-Fired Warm Air Furnace, Single Stage, Category 1, Goodman Manufacturing Co., L.P. GOODMAN MES9 & CES9 FURNACE INSTALLATION INSTRUCTIONS [PDF] (2019) GOODMAN FURNACE HIGH TEMPERATURE PLASTIC VENT HTPV SAFETY RECALL [Web article] US CPSC noticeJan 12, 2023 · Get professional furnace and air conditioning installation, maintenance, and 24-hour repair services with SNAP Heating & Air Conditioning. Our licensed and experienced technicians are available around the clock to provide prompt and reliable service to keep your home comfortable all year long. Jan 18, 2014 · GMVC95 goodman furnace issue I had a brand new GMVC951155DXA installed in my house, along with a Comfortnet CTK03 thermostat, and brand new DSZC16 heat pump. Immediately after starting the system, I had a prompt on the thermostat that says E2 PS1 (Low pressure switch stuck open). Apr 12, 2023 · No signal from the thermostat. Turn off the unit’s power and check connections. Single LIGHT flash. Furnace lockout due to an excessive number of ignition retries. Locate and correct gas interruption. Reset by lowering it for 20 seconds and then raise it back, furnace will reset itself after one hour. 2 LIGHT flashes. To receive the Lifetime Compressor Limited Warranty (good for as long as you own your home), Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year or 2-Year Unit Replacement Limited Warranty, 20-Year Heat Exchanger Limited Warranty, and 10-Year Parts Limited Warranty, online registration must be completed ... Jul 1, 2022 · Brand new and it is a goodman ace furnace dont have the model number with me. Tried the reset - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website. 4th of July Deals - Purchase Your HVAC Equipment Direct ... Code 1-3: Indicates that a limit flame switch problem that normally auto-resets after 3 hours. Code 1-4: Represents an ignition problem. However, the furnace will auto-reset after some hours. Code 2-1: This is a sign of gas heating lockout. You need to check if the gas valve wiring is correct.Apr 12, 2023 · No signal from the thermostat. Turn off the unit’s power and check connections. Single LIGHT flash. Furnace lockout due to an excessive number of ignition retries. Locate and correct gas interruption. Reset by lowering it for 20 seconds and then raise it back, furnace will reset itself after one hour. 2 LIGHT flashes. Open the gas valve fully in a counterclockwise motion to make sure the gas supply is turned on. Increase the temperature on the thermostat, and turn the mode to "Heat" after making sure the vents are all clear of blockages. Disconnect the power to reset the furnace, and contact Trane if necessary.Model of the furnace: Keeprite high efficiency gas furnace Thermostat: Honeywell 4110 PRO Thermostat wiring: 4 wires [No C wire] Heating and cooling: yes I bought a new house and the furnace is one year old. Due to renovations, no one lived here so not sure it has been used. temperatures fell and I started using heating.I have problem with bryant furnace mod#379CAV036070AGJA just to call for heat the board display code #12 (HK42FZ011) so we wait some time and after that the board run a perfect cycle,run inducer,fire …If the furnace is running, turn the thermostat off and allow the furnace to cool and the blower to stop operating. Initiate a call for heat from the thermostat and monitor the ignition sequence. 1. The inducer motor should start with no difficulty. 2. The pressure switch should close within a couple seconds of the inducer starting. 3.As an armature, I have some experience troubleshooting furnace problems. I have a 1.5 ton Goodman furnace that cools and heats. The circuit bd. Is B25578-00A. The unit is 25 years old and has been wor … read more4th of July Deals - Purchase Your HVAC Equipment Direct ... Oct 12, 2017 · Model of the furnace: Keeprite high efficiency gas furnace Thermostat: Honeywell 4110 PRO Thermostat wiring: 4 wires [No C wire] Heating and cooling: yes I bought a new house and the furnace is one year old. Due to renovations, no one lived here so not sure it has been used. temperatures fell and I started using heating. 67. Ambient Temperature Sensor Fault (Out of Range – Open or Shorted) ERR 67. 6 Flash. Coil Temperature Sensor Fault (Out of Range – Open or Shorted) Low Pressure Cut Out Fault (Open outside of defrost Cycle-Hard lock out, cycle power to reset) ERR 79.Goodman furnaces are among the most recognized and respected forced-air heating systems. Its reputation was built on a foundation of quality core product development, manufacturing excellence, and engineering expertise. Keeping that reputation alive means continuous improvement through product innovation and the introduction of new features reflecting advances in technology. Many components ...The duration of warranty coverage in Texas and Florida differs in some cases. ** For installation in California’s South Coast Air Quality Management District (SCAQMD) only: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the ...GMES80-U. Goodman furnace features: Multi-speed motor, ultra-low NOx, fault code LED output, quiet draft inducer. Pros and cons: With an 80 percent AFUE rating, this is one of Goodman’s least efficient furnaces. This is a single-stage model, which means it is a less energy efficient but more affordable option.ItsAShitParty • 1 yr. ago. 1DL means idle as in no the system is not getting any signals from the thermostat. F04 means fan CFM. The 04 would indicate 400 cfm. This is a continuous usually fan CFM. Your system is not getting any heating or cooling signal/running the fan at low speed.Select the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button.Aug 23, 2023 · Last Udated: August 23, 2023. The Goodman 1DL error code is a common problem in Goodman furnaces. It indicates a problem with the low-voltage transformer, which provides power to the furnace’s control board and other components. 67. Ambient Temperature Sensor Fault (Out of Range – Open or Shorted) ERR 67. 6 Flash. Coil Temperature Sensor Fault (Out of Range – Open or Shorted) Low Pressure Cut Out Fault (Open outside of defrost Cycle-Hard lock out, cycle power to reset) ERR 79.Troubleshooting b1 fault code on a Goodman communicating air handler HVAC Technician: airheatman , HVAC Technician replied 7 years ago Take a look at this manual on troubleshooting these motors and let me know if you want to get the tester and determine if issue is in motor or boardFIX: Adjust the gas pressure according to the information available to you. CODE: Eight LED flashes. PROBLEM: This means your furnace has an igniter circuit problem due to a defective igniter or an improperly connected igniter. FIX: Replace the igniter or check the ground wiring for defects. CODE: Nine LED flashes.https://www.alwaysopen.caGoodman Furnace Fault CodesJul 13, 2022 · Goodman furnaces are among the most recognized and respected forced-air heating systems. Its reputation was built on a foundation of quality core product development, manufacturing excellence, and engineering expertise. Keeping that reputation alive means continuous improvement through product innovation and the introduction of new features reflecting advances in technology. Many components ... Some simple Diy troubleshooting a Goodman furnace with no flame and the computer board putting out a number 1 flash code.Amazon link to Great products that e...If the furnace is running, turn the thermostat off and allow the furnace to cool and the blower to stop operating. Initiate a call for heat from the thermostat and monitor the ignition sequence. 1. The inducer motor should start with no difficulty. 2. The pressure switch should close within a couple seconds of the inducer starting. 3.RESULT: No signal from thermostat. FIX: Turn off power and check connections. CODE: One led that flashes. RESULT: Furnace lockout after three attempts to fire. FIX: Locate and correct gas interruption. Reset by lowering it for 20 seconds and then raise it back, furnace will reset itself after one hour.About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ...Mar 26, 2022 · I am always available if you want to use your “Request Call Option “ And if you don’t get another message right after this greeting it’s because I’m more then likely I’m in the process of writing another message to you. that number is ***** the air conditioning coil that is on top of the furnace. Hi just hooked up my Goodman furnace and as soon as I put the power on the 3:00 a.m. fuse blue. AnyHi just hooked up my Goodman furnace and as soon as I put the power on the 3:amp. fuse blew. Any sugg … read moreThe controller will indicate a fault condition by flashing the fault LED. The flashing pattern will be ¼ second on and ¼ second off for each count, if multiple faults are present it will dwell 2 seconds between each fault code, then dwell 5 seconds and repeat until the fault(s) are cleared. Listed below are the fault codes. 1 flash – Not UsedGoodman manufacturing. it is displaying code 1dl and the green light is flashing two long, five short. anything I can - Answered by a verified HVAC Technician- In short: check your fuse on the circuit board. If it's tripped, replace it. I got this 5 amp fuse on Amazon: https://amzn.to/3O5JUko and here's the Nest t... Jan 25, 2020 · 1. the thermostat demand signal is intermittent. 2. Time delay relay or control board faulty. 3. If high pressure switch is present, go to Flash Code 2 information. 4. If a low pressure switch is present, go to Flash Code 1 information. Status LED: Yellow “ALERT” Flash Code 4. Status LED Description: off rotor. The flashing LEDs on your furnace will correspond to a specific fault code that is shown here on their diagnostic chart.Goodman is one of the biggest names i...STATUS: Discharge Air Too Hot. SUGGESTED ACTION: Clean Filter or Remove Air Blockage. CODE: LC. STATUS: Outdoor Coil Thermistor temperature high. SUGGESTED ACTION: Clean Condenser Coils, Check Fan for fault. Code will reset after cleaning. CODE: C2. STATUS: Indoor Air Recirculation. Large delta between thermostat and return.Dec 21, 2011 · AMANA & GOODMAN FAULT CODES. 1. One led flash that stays on continuously = No signal from thermostat. Turn off power and check connections. 2. One led that flashes = Furnace lockout after three attempts to fire. Must be reset by lowering it for twenty seconds and then raise it back. After one hour furnace will reset itself. 3. Most popular furnace brands in Canada There are several popular furnace brands available in Canada, and the most popular ones are: Lennox Carrier Trane Bryant York Goodman Rheem American Standard Armstrong Air Napoleon These brands offer a range of furnace...Sep 29, 2022 · If the furnace is running, turn the thermostat off and allow the furnace to cool and the blower to stop operating. Initiate a call for heat from the thermostat and monitor the ignition sequence. 1. The inducer motor should start with no difficulty. 2. The pressure switch should close within a couple seconds of the inducer starting. 3. 4th of July Deals - Purchase Your HVAC Equipment Direct ... Jul 1, 2022 · Brand new and it is a goodman ace furnace dont have the model number with me. Tried the reset - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website. Purchase Your HVAC Equipment Direct | Goodman AC And Furnace ...Last Udated: August 23, 2023. The Goodman 1DL error code is a common problem in Goodman furnaces. It indicates a problem with the low-voltage transformer, which provides power to the furnace’s control board and other components.goodman furnace tech support. Its a 2018 model goodman and i get 3 led flashes, the igniter glows real bright and then dims. We tried to jump the pressure switch but the furnace did the same thing it … read moreAbout Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ...Troubleshooting b1 fault code on a Goodman communicating air handler HVAC Technician: airheatman , HVAC Technician replied 7 years ago Take a look at this manual on troubleshooting these motors and let me know if you want to get the tester and determine if issue is in motor or boardTo receive the Lifetime Compressor Limited Warranty (good for as long as you own your home), Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year or 2-Year Unit Replacement Limited Warranty, 20-Year Heat Exchanger Limited Warranty, and 10-Year Parts Limited Warranty, online registration must be completed ...Aug 16, 2023 · Possible Causes for 4 flashes on a Goodman furnace. • Check filters andductwork for blockage.Clean filters or removeobstruction. circulator blower speed, orfailed circulator blower. • Check circulator blowerspeed and performance.Correct speed or replaceblower if necessary. • Misaligned burners, blockedflue and/or air inlet pipe, orfailed ... This one covers the IFC error codes for most Trane furnaces. This video is part of the heating and cooling series of training videos made to accompany my we...Brand new and it is a goodman ace furnace dont have the model number with me. Tried the reset - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website.Select the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button.Feb 10, 2023 · Besides Goodman fault codes, there are the messages which can also appear, status and data related to these codes. This information can give you the idea about any necessary further actions – for example, 3 flashes mean that Goodman pressure switch stuck open, and 2 flashes mean the same part stuck closed. Model of the furnace: Keeprite high efficiency gas furnace Thermostat: Honeywell 4110 PRO Thermostat wiring: 4 wires [No C wire] Heating and cooling: yes I bought a new house and the furnace is one year old. Due to renovations, no one lived here so not sure it has been used. temperatures fell and I started using heating.How to Replace Your Air Filter. Open the access door on your Goodman furnace by pulling it towards you, revealing the filter inside. Carefully remove the filter by hand. Vacuum any dust or debris that may have accumulated on the filter housing of the furnace. Slide in the replacement filter.goodman air conditioner error codesFIX: Check your Goodman furnace for a pinched or blocked pressure switch hose. CODE: Continuous LED flashes PROBLEM: This means that your furnace has a reversed polarity of 115 volts. FIX: You will have to correct the wiring polarity after reviewing the wiring diagram. goodman furnace codes Dec 23, 2022 · Goodman manufacturing. it is displaying code 1dl and the green light is flashing two long, five short. anything I can - Answered by a verified HVAC Technician About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ...

Turn off the furnace or the breaker box. Check the filter to make sure it’s clean, and replace it if necessary. Inspect the furnace and vents for dirt and debris, and vacuum them if necessary. Turn the furnace back on. Check that the thermostat is set to Heat and set for higher than room temperature.. 4 plex

1dl code on goodman furnace

We experienced a power outage and when the power came back on our furnace blows cold air but will not ignite. I believe it is a 3 yr. old Goodman model no. CAPF486OC6AA. I noticed a blinking code of 4 … read moreCode 1 – Furnace ignition failure. The control board has detected that the furnace failed to ignite. The control board has detected that the furnace failed to ignite. This could be due to low voltage, high resistance, or dirty terminals on the furnace primary control.May 11, 2019 · STATUS: Discharge Air Too Hot. SUGGESTED ACTION: Clean Filter or Remove Air Blockage. CODE: LC. STATUS: Outdoor Coil Thermistor temperature high. SUGGESTED ACTION: Clean Condenser Coils, Check Fan for fault. Code will reset after cleaning. CODE: C2. STATUS: Indoor Air Recirculation. Large delta between thermostat and return. Turn off the furnace power and repair a short or replace the pressure switch. 4. Read three LED flashes to mean your furnace has an open pressure switch circuit or it has an induced draft blower operating. Check the pressure switch hose of your furnace for blocks or an improper connection.Troubleshooting GMEC96 Fault Status Codes •Fault Code Example 1: Status light displays “4 Red flashes.” •Refer to the “troubleshooting” chart on page 44 of the GMEC96 service manual. •Also, find your “fault symptoms and description” in the troubleshooting chart on pages 42-43.Jan 25, 2020 · 1. the thermostat demand signal is intermittent. 2. Time delay relay or control board faulty. 3. If high pressure switch is present, go to Flash Code 2 information. 4. If a low pressure switch is present, go to Flash Code 1 information. Status LED: Yellow “ALERT” Flash Code 4. Status LED Description: off rotor. Instructions: 1. Select the brand from the drop down menu 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button. © 2011 Goodman Manufacturing Company, LP. All rights reserved.Nov 29, 2014 · A quick look at goodman trouble codes on a goodman furnace. Some simple hints on what those codes can indicate what the problem could be. Amazon link to Gre... Trane furnace code 1dl. Troubleshooting a Trane furnace with code 1DL is a common challenge homeowners face. Code 1DL stands for “Inadequate Diffuser Pressure Switch Closure” and can occur due to problems with the furnace blower motor, evaporation motor, heat exchanger or other related components.Turn off the furnace or the breaker box. Check the filter to make sure it’s clean, and replace it if necessary. Inspect the furnace and vents for dirt and debris, and vacuum them if necessary. Turn the furnace back on. Check that the thermostat is set to Heat and set for higher than room temperature.AC furnace brands AC furnaces, also known as central air conditioning systems, are important to home comfort and energy efficiency. Many AC furnace brands are on the market, each with strengths and weaknesses. Trane is a popular AC furnace brand known for its... RESULT: No signal from thermostat. FIX: Turn off power and check connections. CODE: One led that flashes. RESULT: Furnace lockout after three attempts to fire. FIX: Locate and correct gas interruption. Reset by lowering it for 20 seconds and then raise it back, furnace will reset itself after one hour.ItsAShitParty • 1 yr. ago. 1DL means idle as in no the system is not getting any signals from the thermostat. F04 means fan CFM. The 04 would indicate 400 cfm. This is a continuous usually fan CFM. Your system is not getting any heating or cooling signal/running the fan at low speed. Turn off the furnace or the breaker box. Check the filter to make sure it’s clean, and replace it if necessary. Inspect the furnace and vents for dirt and debris, and vacuum them if necessary. Turn the furnace back on. Check that the thermostat is set to Heat and set for higher than room temperature.Jan 25, 2020 · 1. the thermostat demand signal is intermittent. 2. Time delay relay or control board faulty. 3. If high pressure switch is present, go to Flash Code 2 information. 4. If a low pressure switch is present, go to Flash Code 1 information. Status LED: Yellow “ALERT” Flash Code 4. Status LED Description: off rotor. STATUS: Discharge Air Too Hot. SUGGESTED ACTION: Clean Filter or Remove Air Blockage. CODE: LC. STATUS: Outdoor Coil Thermistor temperature high. SUGGESTED ACTION: Clean Condenser Coils, Check Fan for fault. Code will reset after cleaning. CODE: C2. STATUS: Indoor Air Recirculation. Large delta between thermostat and return.About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ... .